Product Introduction
| Basic features | |||
| Standards | EN/IEC 60898-1 | ||
| Certificate | Dekra/KEMA ,CE,CB | ||
| Electrical features | |||
| Rated current in | A | 6, 10, 16, 20, 25, 32, 40, 50, 63 | |
| Rated voltage Ue | V | 230/400, 240/415 | |
| Rated frequency | Hz | 50/60 | |
| Number of poles | P | 1, 2, 3, 4 | |
| Ultimate short-circuit breaking capacity Icu | kA | 6/10 | |
| Service short-circuit breaking capacity Ics | kA | 6kA(Icu 6kA),7.5kA(Icu 10kA) | |
| Rated insulation voltage Ui | V | 500 | |
| Rated impulse withstand voltage Uimp | kV | 4 | |
| Dielectric test voltage at ind. Freq. for 1 min | kV | 2 | |
| PoIIution degree | 2 | ||
| Trip form | Thermal magnetic trip | ||
| Magnetic release characteristic | B type(3-5In) | ■ | |
| C type(5-10In) | ■ | ||
| D type(10-20In) | ■ | ||
| Thermal release characteristic | 1.13In Non trip cold state | ≤ 63A t ≥ 1h | |
| 1.45In trip after 1.13 test | ≤ 63A t<1h | ||
| Mechanical features | |||
| Mechanical life | T | 10000 | |
| Electrical life | T | 4000 | |
| Reference temperature for setting of thermal element | ℃ | 30,40,50 | |
| Ambient temperature | ℃ | -35~+70℃ | |
| Installation | |||
| Degree of Protection | IP20 | ||
| Nominal cross-sectional area of the copper conductor | mm2 | 25 | |
| Tightening torque | N·m | 2.0 | |
| Line entry | U / Pin-type Busbar / Cable | ||
| Mounting | on Din rail EN50022(35mm) | ||
ETM3 series miniature circuit breaker are applicable to the low-voltage terminal distribution in the industry, civil building such as home and residence, energy, communication, infrastructure, lighting distribution system or motor distribution and other fields. They are used for the short circuit and overload protection, control and isolation. This mounting type MCB is used in almost all the countries and regions all over the world.
ETM3 series MCB is in complied with IEC 60898-1 standard. It has the certification of Dekra / KEMA, CE and CB .
The breaking capacity of ETM3 is 10KA, or 6KA.
The tripping type is B, C, D curve.
The rated current is (1A, 2A, 3A, 4A) 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A.
The tripping type is B, C, D curve.
Rated insulation voltage: AC, 230V, 240V, 230 / 240V (1 Pole); 400 / 415V (2 poles, 3 poles). DC, 250V 1P, 500V 2P, 750V 3P, 1000V 4P.
The ETM3 MCB can work reliably in harsh environment, in ambient temperature from -5°C to 50°C.
The electrical life can be up to 8000 operations and mechanical life up to 20000 operations, while the IEC requirement is only 4000 operations and 10000 operations.
It’s mounting type is to be mounted on din rail EN60715 35mm.
🔧 Product Highlights:
Breaking Capacity: 6kA or 10kA
Trip Curves: B, C, or D type for various protection needs
Current Ratings:
- 1A to 63A, including: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A
- 10A–16A (1P): Ideal for lighting circuits
- 20A–32A: Common for kitchens, bathrooms, and air conditioning
- 40A–63A (2P): Often used as main switches replacing traditional isolators
Voltage Ratings:
AC: 230V / 240V (1P), 400V / 415V (2P and 3P)
Pole Options: 1P, 2P, 3P, and 4P, with each pole occupying a standard 1-inch width
Status Indicator: Clear on/off display — Red = ON, Green = OFF
Terminal Safety: IP20-rated, designed to prevent accidental contact during installation
The ETM6 is built to perform in demanding environments, operating reliably between -5°C to 50°C.
It offers a long service life, with up to 8,000 electrical and 20,000 mechanical operations, far exceeding the minimum IEC requirements.
⚙️ Mounting Style:
Plug-in top terminal with bottom-side wiring for quick and efficient installation.