CE Certification Distribution Board Flush Mounting Factories – MCCB, isolator, MCB main breaker three phase distribution board – Etechin
CE Certification Distribution Board Flush Mounting Factories – MCCB, isolator, MCB main breaker three phase distribution board – Etechin Detail:
Feature
Standard | IEC61439-1&2 Designed to be operated by an ordinary person |
Pan assembly rating(A) | 125,200,250A |
No.of phase | 1,2,3 |
Voltage Rating(V) | 110-415 |
Rated Insulation voltage(V)Ui | 690V |
Mounting type | Flush/Surface |
No. of ways(3phase) | 4,6,8,10,12,14,16,18,20,22,24 |
Ingress protection(IP) | IP40 |
Enclosure material | Electro galvanized steel |
Steel sheet thickness(mm) | 1&1.2mm |
Surface finishing | Powder coated with electrostatic Epoxy polyester(RAL7035) |
Coating thickness | 70-90 microns |
Main incomer breaker | MCCB or MCB, ELCB+ISOLATOR, |
Branch breaker | 1,2,3P din-rail type 18mm width MCB |
Neutral terminal Capacity | Offer 10mm diameter lug hole |
Earth terminal Capacity | Offer 10mm diameter lug hole |
Ambient Temperature(℃) | 30,50 |
Feature
1. Galvanized 1.2mm sheet
2. Main switch: MCB,ISOLATOR,RCCB,MCCB up to 150A
3 .Outgoing: upto 72poles way MCB
4. Plastic Lock/Metal Lock
5. Surface/flush type
6. Adjusted mounting plate
7. Powder coating Ral7035 texture
8. IP42 for Metal Enclosure
9. IEC61439-1
10. Extension Board 12poles way on top and bottom design
11. Adjustable rail suitable for most of the din rail type MCB
12.Door easy removable, and can be installed inversely .
13.Extension board multiple row x 12W available installed on the upper or downer of distribution board.
14.Pan assembly/Busbar system fully tin plated instead of original copper finishing. Provider
more durable of good electrical conductivity away from copper rusting. And shroud plastic cover against 850 ℃ fire glow test/Glow wire test.
Main incomer switch connect to the pan assembly/busbar by solid copper bar.
Dimension
MCB incomer | |||||||
Item No. | main breaker | Outgoing/poles |
H |
H1 |
W |
W1 |
D |
DT02MCB-04 | MCB | 12poles |
560 |
550 |
350 |
340 |
110 |
DT02MCB-06 | MCB | 18poles |
614 |
604 |
350 |
340 |
110 |
DT02MCB-08 | MCB | 24poles |
668 |
658 |
350 |
340 |
110 |
DT02MCB-10 | MCB | 30poles |
722 |
712 |
350 |
340 |
110 |
DT02MCB-12 | MCB | 36poles |
776 |
766 |
350 |
340 |
110 |
DT02MCB-14 | MCB | 42poles |
830 |
820 |
350 |
340 |
110 |
DT02MCB-16 | MCB | 48poles |
884 |
874 |
350 |
340 |
110 |
MCCB 160-200A incomer |
|||||||
DT02MCCB200-04 | MCCB 200A | 12poles |
560 |
550 |
350 |
340 |
110 |
DT02MCCB200-06 | MCCB 200A | 18poles |
614 |
604 |
350 |
340 |
110 |
DT02MCCB200-08 | MCCB 200A | 24poles |
668 |
658 |
350 |
340 |
110 |
DT02MCCB200-10 | MCCB 200A | 30poles |
722 |
712 |
350 |
340 |
110 |
DT02MCCB200-12 | MCCB 200A | 36poles |
776 |
766 |
350 |
340 |
110 |
DT02MCCB200-14 | MCCB 200A | 42poles |
830 |
820 |
350 |
340 |
110 |
DT02MCCB200-16 | MCCB 200A | 48poles |
884 |
874 |
350 |
340 |
110 |
The below diagram indicated the MCCB and MCB main three phase distribution board connection an extension board on the top.
Main Factor effect Cost/Price
1. Thickness and kind of steel:
2. Dimension of the board
3. Structure of the board
Product detail pictures:
Related Product Guide:
We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of CE Certification Distribution Board Flush Mounting Factories – MCCB, isolator, MCB main breaker three phase distribution board – Etechin , The product will supply to all over the world, such as: Nairobi, Saudi Arabia, Ukraine, By continuous innovation, we will present you with more valuable items and services, and also make a contribution for the development of the automobile industry at home and abroad. Both domestic and foreign merchants are strongly welcomed to join us to grow together.
By Lydia from Sri Lanka - 2017.01.28 19:59
Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
By Phoebe from Mali - 2018.06.18 19:26