ETM8 DC MCB
ETM8 DC series miniature circuit breaker are applicable to the low-voltage terminal distribution in the industry civil building such as home and residence energy communication infrastructure lighting distribution system or motor distribution and other fields. They are used for the short circuit and overload protection control and isolation.
Manufacturer OEM
Certificate:KEMA CE CB
Standards:IEC/EN60898-2
Breaking capacity:4.5/6KA
Rated Current:6-63A
Voltage:1P(250V)2P(500V)3P(750V)4P(1000V)
Product Introduction
| Basic features | ||
| Standards | IEC60898-2 | |
| Electrical features | ||
| Rated current In | A | 1,2,3,4,5,6,10,13,16,20,25,32,40,50,63A |
| Poles | P | 1,2,3,4 |
| Rated voltage Ue | V | 1P(250), 2P(500), 3P(750, )4P(1000) |
| Rated breaking capacity | A | 6,000/10,000 |
| Rated impulse withstand voltage Uimp | V | 4,000 |
| Dielectric test voltage at ind. Freq. for 1 min | kV | 2.5 |
| Pollution degree | 2 | |
| Thermo-magnetic release characteristic | In | B type(4-7In),c type(7-15In) |
| Mechanical features | ||
| Electrical life | T | 1500 |
| Mechanical life | T | 10000 |
| Contact position indicator | Yes | |
| Reference temperature for setting of thermal element | ℃ | 30 |
| Ambient temperature (with daily average ≤ 35°℃ ) | ℃ | -5~+40 |
| Storage temperature | ℃ | -25~+70 |
| Installation | ||
| Protection degree | IP20 | |
| Terminal connection type | Cable/Pin-type busbar/U-type busbar | |
| Terminal size top/bottom for cable | mm2 | 25 |
| Terminal size top/bottom for busbar | mm2 | 25 |
| Tightening torque | N·m | 2.0 |
| Mounting | On DIN rail EN50022(35mm) by means of fast clip device | |
| Accessories | ||
| Auxiliary contact | OF | |
| Alarm switch | SD | |
| Shunt release | MX | |
| Over/Under voltage release | MV+MN | |
ETM8 DC series MCB is in complied with IEC 60898-2 standard. It has the certification of Semko, CE, CB.
The breaking capacity of ETM8 DC is 6KA, or 10KA
The tripping type is B, C curve.
The rated current is (1A, 2A, 3A, 4A) 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A. The rated current is related to different area using for example one pole 10a to 16a ampere is normally used for lighting, 20 ampere to 33 ampere is normally used for kitchen and bathroom area, also used for air conditioner and other line equipment. Some customers will choose 2 pole, 40ampere to 63 ampere as main switch instead of isolator.
Rated insulation voltage: 230V, 240V, 230 / 240V (1 Pole); 400 / 415V (2 poles, 3 poles)
It has single pole (1p), double poles (2p), three poles (3p), and four poles, which is one inch breaker sizes per pole.
There is a position indicator equipped on the products, Red is on, Green is off.
The MCB terminals are IP20 protection which is designed for finger and hand touch safe to keep the safety during installation.
The ETM8DC MCB can work reliably in harsh environment, in ambient temperature from -25°C to 55°C.
The electrical life can be up to 8000 operations and mechanical life up to 20000 operations, while the IEC requirement is only 4000 operations and 10000 operations.
The mounting type is plug-in on top terminal ,wiring bottom.
Related Products